plastocor® Inlet and Outlet Protection against Galvanic Corrosion and Step-Erosion

plastocor® Inlet System – your most cost-efficient tool in optimising operational budgets

The original plastocor® Tube End Inlet Coating System P400-IL indefinitely protects and repairs condensers and heat exchanger tubes against inlet and outlet corrosion and erosion. In combination with plastocor® tube sheet cladding, it offers the optimal life extension system of >20 years, plus the elimination of step- and general erosion. Its sophisticated 3-step method allows for expert planning and budget optimisation, saving a plant operator time and money.

plastocor® Inlet System

plastocor® Inlet System with its 3-step method is a quick and simple way to optimise planning and budgets, allowing plant operators to efficiently calculate remaining lifespan of the coated tubes. The three-step method can bridge small perforations of the tube wall repairing the tube, thus postponing or even eliminating the need to retube.

{[image]}

{[title]}

{[text]} More...
 

plastocor® Inlet plus Cladding System

plastocor® Inlet System in combination with the plastocor® Cladding System is a low-cost alternative in the repair of corroded tube sheets and in the protection of condensers and heat exchanger tubes against inlet / outlet end corrosion, as well as step- and general erosion.

{[image]}

{[title]}

{[text]} More...
 

plastocor® Inlet plus Cladding plus Tube Lining System

plastocor® Cladding in combination with the plastocor® Inlet System and plastocor® Tube Lining System is the ultimate protective system for the entire condenser. plastocor® systems, in combination, are designed so as to endure extreme conditions and can be applied in all climatic conditions.

{[image]}

{[title]}

{[text]} More...
 

Why choose plastocor®
Inlet System?

text icon

More than 120’000 operating hours per inlet system

After more than 40’000 operating hours, a cross cut of the coated tubes indicated that another 40’000 plus hours lay ahead until the final layer was reached, which allowed the plant operator to plan and budget.

text icon

No more step-erosion  thanks to feathered termination 

A three-stage method is applied in differently coloured layers with a feathered termination, which eliminates the danger of step-erosion, a common problem with the use of plastic or metal inserts.

text icon

Cost-efficient planning thanks to Three-Stage Method

The multiple-colour coating system makes it possible to calculate the remaining lifespan of the coated tubes by measuring the thickness of the individual coats and translating it into operating hours.

One-Stop Solution

plastocor-international SA one-stop solution prevents and repairs all erosion and corrosion problems along the entire cooling water cycle. Huge savings on operational costs given our fully integrated, compatible package. Let our one-stop solution optimise your plant’s productivity, efficiency and reliability.

Expert Application

Combining expert know-how and skilled application, plastocor® made-to-measure solutions can be applied worldwide, anywhere and in any climatic conditions. We work with locally skilled labour to provide you with the quickest response rate possible to minimise shutdown periods and optimise productivity.

«57 avoided leakages resulted in additional operational profit of 1.18 million € at an investment of 120’000 €. »
Nos Nouvelles,
DF SICN N Service Ingénierie de Cruas
e remove